ElectricPropulsion.org
Repower calculator, guides & CAN tools

VictronConnect Remote (VC-R): configuring a boat's Victron system from anywhere

What VictronConnect-Remote does, what it needs, which products it reaches, how to set it up, and the related VRM tools — Remote VEConfigure and remote firmware updates — with the precautions for a boat, from Victron's manuals.

TTMH9 min read11 sections
Charging
On this page
  1. Victron's remote tools, side by side
  2. What VC-R needs
  3. Setting it up
  4. Which products it reaches
  5. Inverter/chargers: Remote VEConfigure
  6. Remote firmware updates
  7. Security on a boat
  8. When it doesn't work
  9. A checklist for a boat
  10. Sources
  11. Related reading

VictronConnect is the app you use beside a Victron product, over Bluetooth or USB. VictronConnect-Remote (VC-R) opens the same product from anywhere: the app connects through the boat's GX device — a Cerbo GX, for example — and Victron's VRM Portal, and shows the same screens, with "full product configuration and monitoring from practically anywhere in the world", in Victron's words.

This guide covers what VC-R needs, how to set it up, which products it reaches, the related VRM tools for inverter/chargers and firmware, and what's worth leaving until you're back aboard. It is based on Victron's VictronConnect, VRM Portal and GX manuals, linked under Sources.


Victron's remote tools, side by side

ToolOpensUse it for
Remote Console on VRMthe GX device's own menussystem settings, DVCC, notifications, anything on the GX screen
VictronConnect-Remoteindividual products, in the VictronConnect appMPPT, battery monitor, BMS and charger settings and details
Remote VEConfigure (VRM device list)a Multi or Quattro's configuration filechanging inverter/charger settings, which VC-R can't
Remote firmware update (VRM device list)product firmwareupdating connected products when you need to
VRM dashboard and Controlsthe VRM Portal or VRM appmonitoring, and switching the inverter, relay or generator

All of them run through the GX device's connection to VRM, and all of the configuration tools need VRM Portal mode set to Full. The Venus OS guide covers that connection and Remote Console in detail.


What VC-R needs

RequirementDetail
VictronConnect5.20 or later; Victron recommends the latest
GX deviceVenus OS 2.40 or later; 2.53 recommended for full functionality
VRM Portal modeFull, under Settings → VRM → VRM Portal on the GX (called two-way communication before Venus OS 3.50)
VRM accountthe installation linked to the account you sign in with in the app
Internet on the boatan active connection from the GX; a GSM/4G router where there's no marina WiFi
Networkno proxies; traffic to victronenergy.com allowed through any firewall

Two further points from Victron's manuals, both important on a boat:

  • Power the GX from the battery, not from an AC adapter on the inverter/charger's output. Victron requires it for Remote VEConfigure, and its VE.Bus update guide shows why: a GX powered by the inverter goes dark when the inverter switches off, and the system can become unreachable.
  • VC-R adds some load to the GX. Victron notes it slightly increases CPU use, and that large systems may slow down or reboot. A Cerbo GX copes better than older GX devices.

Setting it up

On the boat, once:

  1. Connect the GX device to the internet.
  2. Register it on VRM, and check that the VRM menu on the GX shows recent contact with the portal.
  3. Set VRM Portal to Full.
  4. Update VictronConnect on your phone, tablet or computer to the latest version.

In the app, from anywhere:

  1. Open the VRM tab and tap Sign in to VRM. A browser opens for your VRM login; allow it to hand you back to VictronConnect.
  2. Tap the installation. Mark it as a favourite from the three-dot menu if you have several — favourites sync with VRM.
  3. Overview has buttons for the VRM Portal and Remote Console.
  4. Devices lists the products the GX knows. Tap one: its tabs load one by one, and the settings cog appears at top right once everything has loaded.

To remove the app's access later: menu → Settings → Sign out in the VRM Account section.


Which products it reaches

VC-R reaches products connected to the GX by cable, over VE.Direct, VE.Can or VE.Bus. A product that's only on Bluetooth isn't on the GX, so it isn't in the list.

ConnectionProductsWhat VC-R can do
VE.DirectMPPTs, SmartShunt and BMV battery monitors, VE.Direct chargers and invertersmonitoring and settings
VE.CanVE.Can MPPTs (Tr and MC4 models), Lynx Shunt VE.Can, Lynx Smart BMS and Lynx BMS NG, Inverter RS, Multi RS and MPPT RS, Skylla-i (firmware 1.11 or later)monitoring and settings
VE.BusMultiPlus, Quattro and other VE.Bus inverter/chargersoverview and details only — no settings

Not supported: the old BlueSolar VE.Can MPPT 150/70 and 150/85 (the large case with a display), Lynx Ion, Lynx Ion + Shunt, and the Lynx Ion BMS 150 A to 1000 A. The RS products have VE.Direct too, but must be connected by VE.Can for VC-R.

On an electric boat that covers most of what you'd want to adjust remotely: the MPPTs, the battery monitor, and the Lynx Smart BMS NG that coordinates charging.


Inverter/chargers: Remote VEConfigure

Since VC-R won't change a Multi or Quattro's settings, Victron's route is Remote VEConfigure, on the VRM Portal:

  1. Device list → scroll to the bottom → Remote VEConfigure. The GX reads the settings — about 85 seconds per unit, longer with Assistants.
  2. Download the .RVSC file. Don't open it from the browser.
  3. Open it in VEConfigure on your computer, make the changes, then close VEConfigure and confirm saving.
  4. Back on VRM, Upload the same .RVSC file. The GX checks it before writing it to the VE.Bus system.

It needs Venus OS 2.17 or later, VRM Portal mode Full, and the GX powered from the battery. VE.Bus firmware 416 and 417 can't be configured remotely, and 418 or later needs a GX on 2.10 or later. Single-unit, parallel and three-phase systems are all supported.

Watch out for:

  • Save As breaks it. File → Save As makes a .VSC file, which can't be uploaded. Only the original .RVSC works.
  • Some changes restart the inverter. Changing Assistants, for example, switches the inverter/charger off and on briefly; VEConfigure warns you when you save. AC loads lose power for that moment — and so does an internet router powered from the inverter's output, which can cut you off until it's back.

Remote firmware updates

From the VRM Portal's Device list, the firmware update button lists products with newer firmware and an Update button for each. It covers VE.Direct products (MPPTs, SmartShunt, BMV, Orion XS, Smart IP43 chargers and others) and VE.Can products (MPPTs, Skylla-i, the RS range, Lynx Smart BMS). GX mode Full is required.

Victron's main advice is blunt: "Our main advice is to not update a running system, unless there are problems with it." And:

  • A VE.Direct MPPT whose update fails may lose its configuration — and can't then be reconfigured remotely.
  • BMVs connected through a VE.Can interface can't be updated remotely.

VE.Bus inverter/chargers have their own procedure, with stricter requirements: Venus OS 2.65 or later, VE.Bus firmware 426 or later, no VE.Bus BMS (except a V2) or Digital Multi Control on the bus, and VRM mode Full. During the update the inverter is off. Afterwards, settings return to defaults and the charge voltages are set to the nominal battery voltage — which effectively disables the charger until the settings file is converted and uploaded with Remote VEConfigure, the procedure's second stage. Victron notes that a system with a managed battery on CAN-bus keeps charging within the BMS's limits.

On a boat, that makes remote VE.Bus updates a job for when someone is aboard, or at least for a moment when losing shore charging for a while doesn't matter.


Security on a boat

VRM Portal mode Full is what lets VC-R, Remote VEConfigure and remote updates change things. Anyone who can sign in to VRM with access to your installation can, in principle, change charge settings on your boat.

  • Keep your VRM password strong and private, and give other people only the access they need through the installation's settings on VRM.
  • If you only want to watch from home, set VRM Portal mode to Read-only: data still reaches VRM and Remote Console still shows the system, but nothing can be changed and VC-R and remote firmware updates are off. The Venus OS guide has Victron's full table of modes.
  • Sign out of VictronConnect on devices you no longer use.

When it doesn't work

SymptomCheck
No VRM tab in the appupdate VictronConnect to 5.20 or later
Installation offline or missingit's online on VRM, linked to your account, VRM mode Full, Venus OS new enough
A product isn't listedit's connected to the GX by VE.Direct or VE.Can cable at both ends, with recent firmware
Slow to loadthe boat's connection; the cog only appears once every setting has loaded

Victron's error codes:

CodeMeaning
−100the device list request timed out after 60 seconds, usually a poor connection
1no link to VRM — check the internet connection and retry
2VRM has temporary difficulties — try later
5the local system is out of resources
8network error, such as an unplugged cable
13proxy authentication error — proxies aren't supported
14the secure connection to VRM failed
65538VRM's MQTT broker isn't responding — try later

For anything else that persists, Victron asks for a service report from the app.


A checklist for a boat

  • GX powered from the battery, with the router on a supply that survives the inverter switching off.
  • VRM Portal mode Full only if you'll configure remotely; Read-only otherwise.
  • Small, reversible changes remotely — an MPPT setting, a battery monitor value. Inverter/charger reconfiguration and firmware updates when someone is aboard.
  • Record any setting before changing it, so you can put it back.
  • A strong VRM password, and access shared sparingly.

Sources

Checked on 16 November 2026:

We are not affiliated with Victron Energy.


Want exact numbers for your boat?

Use the configurator to generate a vendor-ready spec sheet.

Start the configurator
TPublished by TMHNovember 16, 2026
About & methodology