A Cerbo GX is a small Linux computer. Its software, Venus OS, is open source, and with root access you can do far more than the menus allow — read any value on the system, change settings from a script, run your own code. You can also break things in ways a factory reset won't fix.
This guide covers how Venus OS is put together, the ways to reach a Cerbo from somewhere else, how to turn on SSH, and how to read and change settings from the command line. Everything is from Victron's Cerbo GX manual, its root-access and Venus OS Large pages, the Venus OS changelog and Victron's open-source code on GitHub, linked under Sources. The menus quoted are those of the New UI (gui-v2) on Venus OS 3.50 and later.
Before you start. Victron's root-access page warns that changes to the system "will be lost in case of a firmware update", and that bricking the device is unlikely "but its certainly possible". On a boat the Cerbo coordinates charging and the BMS, so experiment on a spare unit or a Raspberry Pi running Venus OS — Victron recommends the same — not on the device running your propulsion bank.
How Venus OS is built
Two firmware slots and a data partition. The firmware is installed as a complete image, and the previous one is kept: Settings → General → Firmware → Stored backup firmware boots it, and the current version becomes the new backup. Your settings, logs and your own files live separately in /data, which survives updates. Everything outside /data is replaced by the next update.
A read-only root filesystem. The system partition is mounted read-only and has about 5% free space. That's deliberate: it keeps the image intact between updates.
Normal and Large images. Under Settings → General → Firmware → Online updates, the image type can be Normal or Large. Large adds Node-RED and Signal K server. They're resource-hungry; Cerbo GX MK3 vs MK2 covers when that matters.
D-Bus is the backbone. Every device the Cerbo knows about is a D-Bus service with paths:
| Service | What it is |
|---|---|
com.victronenergy.battery.* | each battery monitor or BMS |
com.victronenergy.vebus.* | the inverter/charger system |
com.victronenergy.solarcharger.* | each MPPT |
com.victronenergy.motordrive.* | an electric motor drive (see the motor drive guide) |
com.victronenergy.system | the system overview: main battery SoC, voltage, current, PV power, AC sources |
com.victronenergy.settings | every setting you can change in the menus — and more |
The display, VRM, Modbus TCP and MQTT all read from D-Bus. So does anything you write yourself.
Services run under daemontools. Each program is a service under /service, with its log in /log/<service>/current. Changes under /service don't survive a reboot.
Ways in, and what each is for
| Route | Needs | Use it for |
|---|---|---|
| GX Touch screen | the screen | everything in the menus |
| Remote Console on LAN | same network; http://venus.local or the IP | the same menus in a browser |
| VictronConnect over Bluetooth | phone within about 10 m | initial setup and network settings only |
| Remote Console on VRM | internet on the boat, VRM account | the menus from anywhere |
| VictronConnect-Remote via VRM | internet, VRM Portal mode Full | configuring connected Victron products remotely |
| Modbus TCP, MQTT | same network | reading and writing values from other software |
| SSH | same network, root access | the command line |
Only the last row gives you a shell, and Victron provides it on the local network only.
Step 1: lock down local access first
Since Venus OS 3.50, a local network security profile controls everything reachable over Ethernet or WiFi — Remote Console in a browser, MQTT, the web apps. Set it under Settings → General → Access & Security → Local network security profile:
| Profile | What the menu says |
|---|---|
| Secured (default on new devices) | "Local network services are password protected", "The network communication is encrypted", "A secure connection with VRM is enabled", "Insecure settings cannot be enabled" |
| Weak | Password protected; "Unencrypted access to local websites is enabled as well (HTTP/HTTPS)" |
| Unsecured | "Local network services do not need a password"; unencrypted access enabled |
Units shipped with 3.50 or later come with a password: the six-digit Bluetooth PIN printed on the enclosure. On Secured, your browser shows a certificate warning the first time; accept it, and the login lasts 365 days.
The marine MFD trade-off. Victron's manual says Garmin's MFD app needs the profile set to Unsecured, or the app won't appear, and recommends Unsecured for other brands too to avoid repeated login prompts. If you do that, anyone on the boat's WiFi can change settings — so keep the WiFi password tight and guests on a separate network.
Lost the password? A long press of the Cerbo's push-button resets the network settings and passwords: Ethernet to DHCP, the WiFi access point on, the Remote Console password off, Remote Console on LAN and VRM enabled, and the Bluetooth PIN reset. A "reset to factory defaults" USB stick is the other route.
Step 2: remote access through VRM
This is the supported way to reach the boat from home, and it needs nothing from the marina's router.
- Connect the Cerbo to the internet: the boat's router, marina WiFi or a 4G router.
- Register it at vrm.victronenergy.com. Settings → VRM also has a link button for this.
- Check VRM Portal mode under Settings → VRM → VRM Portal:
| Mode | Data to VRM | Remote Console and Controls | VictronConnect-Remote and remote firmware updates |
|---|---|---|---|
| Full (default) | yes | full control | yes |
| Read-only | yes | view only, no changes | no |
| Off | no | no | no |
- On VRM, open the installation and choose Remote Console.
What goes over the internet. Data goes to ccgxlogging.victronenergy.com over HTTPS on port 443. Remote Console on VRM and Victron's Remote Support use an outbound reverse-SSH connection to Victron's relay servers, trying ports 22, 80 and 443 in turn. Victron's manual says plainly: "No port forwarding or other internet router configuration is necessary". If Remote Console on VRM won't connect, its troubleshooting step is to open https://ccgxlogging.victronenergy.com/ in a browser on the same network: a 403 or 405 error means the connection works, and a timeout means a firewall is blocking it.
Remote Support is not remote SSH for you. Settings → General → Access & Security → Remote support opens a tunnel for Victron's engineers when you ask them for help. Leave it off otherwise; it's off by default.
On a metered 4G connection, Read-only cuts what the boat can do remotely without cutting logging, and VRM lets you turn off real-time mode to save data.
Step 3: command line from outside the boat
Victron doesn't offer SSH over the internet, and you shouldn't create it by forwarding port 22 on the boat's router to the Cerbo: that puts a root login on the open internet. The sound pattern is to join the boat's network over a VPN, then SSH as if you were aboard.
- A VPN on the boat's router. Many 4G and marine routers run WireGuard or OpenVPN, or a Tailscale client. Nothing changes on the Cerbo, and a firmware update can't remove it. This is the option to prefer.
- WireGuard on the Cerbo. Since Venus OS 3.20,
wireguard-toolsis an optional opkg package and the kernel has the WireGuard driver. Packages installed with opkg are removed by each firmware update, so you'd reinstall it from/data/rc.localor by hand after updating. - Tailscale on the Cerbo. Venus OS 3.40 enabled the kernel modules Tailscale needs, and community packages install it. Victron's own GUI code contained a Tailscale settings page during 2024–25, but it was removed in September 2025, so treat any Tailscale add-on as unsupported community software.
Whatever you choose, test it at the dock, and keep VRM as your fallback way in.
Step 4: enable SSH
From Victron's root-access page and the Access & Security menu:
- Raise the access level to Superuser. Under Settings → General → Access & Security, set Access level to User & Installer. Then highlight Access level without opening it and hold the right-hand button until it changes to Superuser. On a touchscreen or in Remote Console, drag the menu down and hold for about five seconds.
- Set a root password in the same menu: at least six characters. Victron advises a complex one, used once to install an SSH key.
- Enable SSH on LAN.
- Log in as root:
ssh root@venus.local
- Switch to keys. Put your public key in
~/.ssh/authorized_keys. Victron notes that keys are stored on the data partition, so they survive updates. Once key login works, Victron's page gives this to disable password logins for root:
echo 'root:*' | chpasswd -e
A firmware update resets the root password, which is another reason to use keys.
Step 5: find your way around
Files that survive and files that don't
| Path | Survives a firmware update? | Notes |
|---|---|---|
/data | yes | settings, logs, your scripts |
/data/rcS.local, /data/rc.local | yes | run early and late during boot — the place for your own start-up commands |
| everything else | no | read-only, replaced by updates |
To change the root filesystem anyway, mount -o remount,rw / makes it writable until the next reboot, and /opt/victronenergy/swupdate-scripts/remount-rw.sh until the next firmware update. If Modifications enabled is switched off under Settings → General → Modification checks, Venus OS renames rc.local and rcS.local to *.disabled at every boot — a quick way to rule out your own changes when something misbehaves.
Reading D-Bus
The dbus command is installed. Always use -y, for the system bus:
dbus -y # list every service
dbus -y com.victronenergy.system /Dc/Battery/Soc GetValue
dbus -y com.victronenergy.battery.<service-name> / GetValue # every value of one service
dbus -y com.victronenergy.settings # list every settings path
/ GetValue doesn't work on some Python services, including the settings service; list the paths instead. For browsing, dbus-spy is better: arrow keys to move, Enter to open a service or edit a value, t to toggle values and text, q to quit.
Services and logs
svstat /service/* # what's running
svc -d /service/<name> # stop a service
svc -u /service/<name> # start it again
tail -F /log/<name>/current | tai64nlocal # follow its log with readable timestamps
grep -h -i error /log/*/current | tai64nlocal
Victron's own diagnostic examples look at the vrmlogger, mk2 and dbus-systemcalc-py logs.
Installing packages
/opt/victronenergy/swupdate-scripts/set-feed.sh release
opkg update
opkg list | grep <name>
opkg install <name>
Only packages Victron has built are available, the feed must match your firmware (release for official versions, candidate for betas), and every firmware update removes them.
Step 6: change settings from the command line
Settings are D-Bus paths in com.victronenergy.settings. The pattern is always the same: read, change, read back.
dbus -y com.victronenergy.settings /Settings/Services/Modbus GetValue
dbus -y com.victronenergy.settings /Settings/Services/Modbus SetValue 1
dbus -y com.victronenergy.settings /Settings/Services/Modbus GetValue
The paths below are the ones the menus themselves use, taken from Victron's open-source GUI code; the values are the menu options in order.
| Path | Menu | Values |
|---|---|---|
/Settings/System/SSHLocal | SSH on LAN | 0 off, 1 on |
/Settings/System/RemoteSupport | Remote support | 0 off, 1 on |
/Settings/System/AccessLevel | Access level | 0 User, 1 User & Installer, 2 Superuser, 3 Service |
/Settings/System/SecurityProfile | Local network security profile | 0 Secured, 1 Weak, 2 Unsecured — read only from the shell, see below |
/Settings/Network/VrmPortal | VRM Portal mode | 0 Off, 1 Read-only, 2 Full |
/Settings/Services/Modbus | Modbus TCP server | 0 off, 1 on |
/Settings/Services/MqttLocal | MQTT access | 0 off, 1 on, 2 paired devices only |
/Settings/System/AutoUpdate | Automatic updates | 0 disabled, 1 check and update, 2 check only, 3 check and download |
/Settings/System/ReleaseType | Update feed | 0 official release, 1 beta |
/Settings/System/ImageType | Image type | 0 Normal, 1 Large |
/Settings/Services/Bol | DVCC | 0 off, 1 on |
/Settings/SystemSetup/MaxChargeCurrent | DVCC maximum charge current | amps; −1 = no limit |
/Settings/SystemSetup/MaxChargeVoltage | DVCC managed-battery charge voltage limit | volts; 0 = off |
Node-RED and Signal K are switched on a different service, com.victronenergy.platform, at /Services/NodeRed/Mode (0 disabled, 1 enabled, 2 enabled in safe mode) and /Services/SignalK/Enabled.
Victron's own example of a shell change is turning SSH off:
dbus -y com.victronenergy.settings /Settings/System/SSHLocal SetValue 0
Three cautions.
- Use the menu for the security profile. The menu changes it through a separate call that sets the password at the same time, so don't write the path directly.
- Some settings have side effects the menu handles for you. Switching DVCC off with Multis present, for example, makes the menu warn you to reset the VE.Bus system. Writing the path skips that warning.
- A wrong value can cut you off. Turning VRM Portal mode off or SSH off from a remote session ends that session. Do it from the boat, or know your way back in.
Updating firmware from the shell
The updater is a script, with these options in its own help text:
/opt/victronenergy/swupdate-scripts/check-updates.sh -check # only check
/opt/victronenergy/swupdate-scripts/check-updates.sh -update # check and install if newer
/opt/victronenergy/swupdate-scripts/check-updates.sh -offline # look for an image on USB or microSD
It uses the feed and image type set in the two settings above. -force reinstalls even when the version is the same or older. Victron's manual recommends keeping automatic updates off on most systems and updating "at a convenient moment; when people are on location and ready to revert" — on a boat, at the dock, not before a passage.
A checklist for a boat
- Security profile Secured, unless an MFD app needs Unsecured — and then a strong WiFi password and a separate guest network.
- VRM registered, Portal mode Full if you want to fix things from home, Read-only if you only want to watch.
- No ports forwarded to the Cerbo. A VPN on the router for command-line access.
- SSH with keys only, and off when you don't need it.
- Your own changes in
/data/rc.local, so they survive updates and you know where they all are. - Firmware updates at the dock, with the stored backup firmware as your way back.
Sources
Checked on 15 November 2026:
- Victron Energy — Ekrano GX, Cerbo GX, Nucleo GX manual: network security profile and password recovery, push-button reset, VRM Portal modes, outbound connections and ports, Remote Console troubleshooting, stored backup firmware, update advice, MFD app requirement
- Victron Energy — Cerbo GX manual: Accessing the GX device and Configuration: access routes and menu paths
- Victron Energy — Venus OS: Root access: Superuser access level, root password, SSH on LAN, keys, read-only rootfs,
/dataandrc.local, modification checks, the D-BusSetValueexample - Victron Energy — Venus OS Large: image type, Node-RED and Signal K, support statement
- Victron Energy on GitHub — Venus OS wiki: commandline development and D-Bus:
dbus,dbus-spy, daemontools, logs, opkg, the system service - Victron Energy on GitHub — gui-v2 (commit of 13 November 2026): settings paths and values used by the menus, security profile texts, the Tailscale page's addition (2024) and removal (September 2025)
- Victron Energy on GitHub — meta-victronenergy
check-updates.sh: updater options and feed and image-type values - Victron Energy — Venus OS firmware change log (via a Victron distributor's copy): security profile and VRM Portal mode introduced in 3.50, WireGuard in 3.20, Tailscale kernel modules in 3.40
We are not affiliated with Victron Energy.
Related reading
- VRM Portal for boats — alarms, geofence and data use once VRM is connected
- A Raspberry Pi instead of a Cerbo GX — the same Venus OS on a DIY build
- VictronConnect Remote (VC-R) — configuring individual products through VRM
- Node-RED on a Cerbo GX — automations without the command line
- Signal K on a Cerbo GX — one data hub for navigation and electrical data
- Cerbo GX MK3 vs MK2 — when Node-RED and Signal K need the faster processor
- Victron Lithium NG and the Lynx Smart BMS NG — reading battery data over Modbus TCP and MQTT, with code
- Motor drives on a Cerbo GX — the motordrive service and its D-Bus paths
- Cerbo GX vs Cerbo GX MK2 — what a Cerbo does on a boat
Want exact numbers for your boat?
Use the configurator to generate a vendor-ready spec sheet.
Start the configurator