How it works: two checks, the larger wire wins
ABYC's E-11 standard requires a boat's DC conductors to meet both their required ampacity and the applicable voltage-drop limit; when the two give different sizes, the larger one is used. The calculator does both:
- Heat (allowable current). From Table 5 of US Coast Guard regulation 33 CFR 183.425, by AWG size and insulation rating, multiplied by the table's correction for engine spaces (0.85 for 105 °C insulation) and for bundles of three or more current-carrying conductors (0.70 for three, down to 0.40 for 25 or more).
- Voltage drop. Current × copper resistance over the round trip, as a percentage of the system voltage, against ABYC's limits.
ABYC's voltage-drop limits
| Maximum drop | For |
|---|---|
| 3 % | Panelboard main feeders, bilge blowers, electronic equipment, navigation lights, and other circuits where drop should be kept to a minimum |
| 10 % | Lighting other than navigation lights, and other circuits where drop isn't critical |
At 12 V, 3 % is just 0.36 V — which is why long runs on a 12 V boat end up with much thicker wire than the current alone needs. The same load at 24 or 48 V draws a half or a quarter of the current and allows twice or four times the volts of drop.
Worked example
A 20 A load, 5 m from the panel on a 12 V boat, on a 3 % circuit: the round trip is 10 m. 18 AWG would carry 20 A without overheating (with 105 °C insulation), but drops far too much voltage. 8 AWG drops 3.4 %; 6 AWG drops 2.2 %, so 6 AWG it is — or 10 mm² metric cable, at 2.9 %. Voltage drop, not heat, decides almost every long, low-voltage run.
Propulsion cables
Main battery and motor cables carry hundreds of amps, often beyond 4/0 AWG. For those, the configurator sizes the cable with the rest of the propulsion system, and the cable sizing guide and DC safety guide cover fusing and the parts around it.
Questions
How do I choose the wire size for a boat circuit?
Check two things and use the larger wire: the allowable current (ampacity) for the wire's size, insulation rating and location, and the voltage drop over the round-trip length. ABYC's limit is 3 % for panel main feeders, bilge blowers, electronics and navigation lights, and 10 % for other lighting and non-critical circuits.
Is the length one way or round trip?
Voltage drop uses the round trip: from the positive source to the load and back to the negative. Enter the one-way distance in the calculator; it doubles it.
What is the allowable current of marine wire?
This calculator uses Table 5 of US Coast Guard regulation 33 CFR 183.425, which lists allowable amperage by AWG size and insulation temperature rating. For example, 10 AWG with 105 °C insulation is rated 60 A outside engine spaces. In an engine space it's multiplied by 0.85, and bundles of three or more current-carrying conductors take a further correction.
What metric cable size matches an AWG size?
The calculator shows each AWG size's cross-section in mm² and suggests the smallest standard metric size that meets the voltage drop and has at least the cross-section of the AWG size the ampacity table requires.