ElectricPropulsion.org
Repower calculator, guides & CAN tools

Victron DVCC explained: how a GX device controls battery charging

What DVCC does, the charge and discharge limits a managed battery sends, which batteries and chargers it can control, its requirements, and how to set it up on a boat — from Victron's GX manual.

TTMH14 min read11 sections
Batteries
On this page
  1. Without DVCC, and with it
  2. The three limits a managed battery sends
  3. What DVCC controls — and what it doesn't
  4. The features every DVCC system gets
  5. Which batteries DVCC can control
  6. Requirements
  7. Setting it up
  8. On an electric boat: the 35-footer
  9. Mistakes to avoid
  10. Sources
  11. Related reading

A boat with lithium batteries often has three or four things charging the same bank: an inverter/charger on shore power, one or more MPPT solar chargers, a DC-DC charger or an alternator. Left alone, each follows its own charge settings, measures voltage at its own terminals, and has no idea what the others are doing — or what the battery can take right now.

DVCC — Distributed Voltage and Current Control — is Victron's answer. Switched on in a GX device such as the Cerbo GX, it "changes the GX device from a passive monitor into an active system controller". This guide explains what it controls, the limits a battery sends it, which batteries and chargers it works with, what it needs, and how to set it up. Everything is from Victron's GX manual and battery compatibility pages, linked under Sources.


Without DVCC, and with it

Without DVCCWith DVCC
Charge algorithmEach charger runs its own bulk, absorption and floatWith a managed battery, chargers follow the battery's voltage and current limits; otherwise each runs its own algorithm with shared measurements
Total charge currentThe sum of whatever every charger decidesOne system limit, set by you or by the battery's BMS (the lower wins)
VoltageEach charger measures at its own terminals, after cable lossesOne battery voltage shared with all chargers (SVS)
TemperatureEach charger uses its own sensor, or noneOne battery temperature shared with all chargers (STS)
Ending absorption on tail currentEach MPPT sees only its own outputMPPTs and Orion XS see the real battery current (SCS)

Which of these you get depends on the battery. A managed lithium battery gets all of them; a lead-acid or non-communicating battery gets the shared measurements and the current limit.


The three limits a managed battery sends

A managed battery — one whose BMS talks to the GX over CAN-bus — sends three values:

LimitMeaning
CVL — charge voltage limitThe highest charge voltage the battery accepts right now
CCL — charge current limitThe most charge current it wants right now
DCL — discharge current limitThe most discharge current it allows right now

Some batteries send fixed values; others change them as conditions change — Victron's examples are limits worked out from cell voltages, state of charge or temperature. The GX passes them on to the inverter/chargers, solar chargers and Orion XS DC-DC chargers, which "disable their own charging algorithms and follow the battery's instructions directly". Their displays then show Ext. control instead of bulk, absorption or float.

Two consequences:

  • Charge voltages set in VEConfigure or VictronConnect stop mattering. Victron's manual says configuring them "is unnecessary and has no effect": the chargers use the voltage the battery sends. That includes systems with a Lynx Smart BMS or Lynx Smart BMS NG.
  • DCL can switch the inverter off. When inverting, Multis and Quattros "will shut down if the maximum discharge current is set to zero", and restart when shore power returns or the BMS raises the limit again. On a boat, that means the AC outlets go dead when the BMS stops discharge — by design.

With a CAN-bus managed battery, Victron says there's no need to wire allowed-to-charge and allowed-to-discharge signals to a Multi or Quattro: the limits arrive over the network.


What DVCC controls — and what it doesn't

Controlled by DVCCNot controlled
The Multi/Quattro system on the GX's built-in VE.Bus port (one unit, or a parallel or three-phase system)A second Multi/Quattro connected through an MK3-USB interface — unless Managed battery controls all Multis and Quattros is switched on
MPPT solar chargers, VE.Direct and VE.Can, including MPPT RSOlder VE.Can MPPTs with a screen ("cannot be used")
Orion XS DC-DC chargersSkylla-i and other chargers
Inverter RS and Multi RSAlternators with no connection to the GX
Wakespeed WS500 and Arco Zeus alternator regulators, when set up as Victron describesLoads — including a propulsion motor controller

Victron puts it plainly: "the total charge current of the inverter/chargers and all MPPT solar chargers will be controlled, nothing else. Any other sources will be extra charge current, unaccounted for." Everything outside the left-hand column needs to be switched by the BMS's allowed-to-charge (ATC) and allowed-to-discharge (ATD) signals instead.

For an electric boat, the motor controller matters most. DVCC doesn't reach it. The motor stops drawing current when the BMS opens its ATD contact or its contactor, or when the controller reads the BMS's limits over its own CAN connection — see the BMS guide and the DC safety guide.

Alternator regulators. The WS500 needs Venus OS 3.30 or later, WS500 firmware 2.5.2 or later and the Wakespeed shunt at the alternator for DVCC control. The Arco Zeus needs Venus OS 3.50, Zeus firmware 1.25, Victron Follower sync mode and an alternator shunt. Both connect to the VE.Can port, not the BMS-Can port.

Several Multis. With Managed battery controls all Multis and Quattros on, every unit receives the full CCL — it isn't shared between them. Victron leaves it to the installer to make sure the total stays within the battery's limit when several charge at once.


The features every DVCC system gets

Limit charge current

A system-wide maximum charge current, under Settings → System Setup → Charge Control. How it works, from Victron's manual:

  • The lower limit wins. With a CAN-bus BMS, the system uses whichever is lower: your setting or the BMS's CCL.
  • Solar first. When chargers have to back off, the order in which they keep their share is: MPPT solar chargers, then Orion XS DC-DC chargers, then inverter/chargers. So the sun is used before shore power.
  • AC loads are compensated. If the inverter/charger is supplying 10 A of AC loads and the limit is 50 A, the solar chargers may deliver 60 A.
  • DC loads only with a shunt. Without one, a 50 A limit with 20 A of DC loads leaves 30 A for the battery. With a SmartShunt or BMV-712 set up as a DC system meter reading 25 A, the chargers are allowed 75 A. Several DC-system shunts are added together, which suits a catamaran with loads in both hulls.
  • Each charger's own limit still applies. If a Multi is set to 50 A in VEConfigure and the GX limit is 100 A, the Multi delivers 50 A at most.

Shared Voltage Sense (SVS)

The GX sends one battery voltage to all chargers — from the BMS or a battery monitor if there is one, otherwise from the VE.Bus system — so they don't charge to a voltage measured after their own cable losses. It's on by default with DVCC, forced on with a Lynx Smart BMS or Lynx Smart BMS NG, and forced off for some batteries.

Shared Temperature Sense (STS)

One battery temperature, from a battery monitor, the GX's temperature input, a Multi or an MPPT with a sensor, sent to every charger for temperature compensation. It is forced off for the Lynx BMSes and some managed batteries, which handle temperature themselves.

Shared Current Sense (SCS)

The battery current from a battery monitor, sent to the MPPTs and Orion XS so they can end absorption on the battery's real tail current rather than their own output. Only for systems without ESS and without a managed battery, and it needs MPPT firmware 1.47 or later.

Controlling BMS

With more than one BMS, this picks the one DVCC follows. It also lets a BMV or SmartShunt be the battery monitor for state of charge while the BMS still controls charging.

Limit managed battery charge voltage

A temporary lower charge voltage for batteries, such as BYD and Pylontech, that need it during commissioning. Victron is emphatic: "Do not use this feature for other purposes" — leaving it on can stop the cells balancing and lead to "severe long-term imbalance".


Which batteries DVCC can control

Supported without conditions

Victron's manual lists DVCC as "fully supported and can be used without issue" for:

  • Lead-acid: gel, AGM, OPzS and others
  • Victron Lithium Smart with a VE.Bus BMS, Lynx Ion + Shunt or Lynx Ion BMS
  • Victron Lithium NG with a VE.Bus BMS NG

With a Lynx Smart BMS or Lynx BMS NG, DVCC "is automatically enabled and cannot be disabled". With a VE.Bus BMS V2 or VE.Bus BMS NG, DVCC must be on for the GX to control the solar chargers, Inverter RS or Multi RS.

Third-party managed batteries

For a battery that talks to the GX over CAN-bus, the rule is strict: "Only enable DVCC if it is explicitly listed as supported for your battery type", and "If DVCC is not mentioned in notes relating to your battery, do not enable it." Victron's battery compatibility pages give each tested battery's required settings — some enable DVCC automatically and force SVS and STS off, others need it switched on by hand.

Brands on Victron's tested list include BYD, Pylontech, MG Energy Systems, Freedom Won, BMZ, Discover, Dyness, Pytes, BattleBorn, SimpliPhi and others; check the current list before buying. Victron also lists third-party BMSes "known to correctly follow the Victron battery specification" — REC, Batrium, 123SmartBMS and Boostech — but "not tested by Victron", with "very limited support". Batteries off the list are untested; Victron says using them "is permitted under warranty", with support from your local supplier.

For MG Energy Systems on a boat, MG's own installation guide says to select the MG NMEA2000 protocol and choose the MG BMS as the controlling BMS; the MG guide covers its messages.

Batteries that don't communicate

A drop-in lithium battery with no CAN connection is a "normal battery" to DVCC. The chargers keep their own charge algorithms, so set each one's charge voltages from the battery maker's figures. DVCC still adds the system charge current limit and, with a BMV or SmartShunt, shared voltage and current sense. What it can't do is react to the battery's BMS: protection then depends on the battery's internal BMS and on ATC/ATD signals wired to the chargers that can accept them.

From Victron's table:

Lead-acidVE.Bus BMS V1 lithiumVE.Bus BMS V2 / NG lithiumThird-party managed
System charge current limityesyesyesper compatibility page
SVSyeswith a BMV or SmartShuntwith a BMV or SmartShuntper compatibility page
STSyesnonoper compatibility page
SCSyeswith a BMV or SmartShuntwith a BMV or SmartShuntper compatibility page
Wire ATC and ATD—yesonly for loads and chargers DVCC doesn't controlper compatibility page

In an ESS system Victron recommends leaving SVS and SCS off, because the VE.Bus device already synchronises the solar chargers. ESS is for grid-connected systems; Victron notes it is "not to be confused with an off-grid system such as is used in boats".


Requirements

1. A battery DVCC supports — see above.

2. Firmware. Victron's minimum versions:

ProductMinimum firmware
GX device2.12
Multi/Quattro422
MultiGrid424
Multi RS, Inverter RS, MPPT RS1.08
VE.Direct MPPTs1.46
VE.Can MPPTs with VE.Direct1.04
Older VE.Can MPPTs with a screencannot be used
Lynx Ion + Shunt2.04
Lynx Ion BMS1.09
Lynx Smart BMS1.02
Lynx BMS NG1.10
Orion XS1.00

Install the latest firmware during commissioning. If anything is below the minimum, the GX shows Error #48 – DVCC with incompatible firmware. In an ESS system, the ESS assistant must be version 164 or later.

3. The right CAN connection. A managed battery connects to a GX CAN port set to the profile its maker specifies — Settings → Connectivity → VE.Can port → CAN-bus profile:

ProfileSpeedFor
VE.Can250 kbit/sVictron products, Lynx BMSes, MG, alternator regulators
BMS-Can500 kbit/smanaged batteries such as BYD, Pylontech, Freedom Won
CAN-bus BMS250 kbit/sbatteries that specify it

VE.Can and BMS-Can "must not share the same bus". A boat with both needs a GX with two CAN buses, such as the Cerbo GX MK2 or MK3 — see Cerbo GX vs Cerbo GX MK2.

4. The chargers on the GX. A charger has to be connected to the GX — VE.Bus, VE.Direct, VE.Can or USB — for DVCC to control it.


Setting it up

  1. Update every device's firmware.
  2. Connect the battery's BMS to the right CAN port and profile, and check it appears in the device list.
  3. Settings → System Setup → Charge Control: switch DVCC on (with a Lynx Smart BMS it already is).
  4. Set Limit charge current if you want a system limit below the battery's own — to protect a lead-acid bank, or to keep a generator within its rating.
  5. Set SVS, STS and SCS as the battery's compatibility page or the table above says.
  6. Choose the controlling BMS if there's more than one, and the battery monitor under Settings → System Setup → Batteries.
  7. Set up any SmartShunt measuring house loads as a DC system meter, so DVCC can compensate for them.
  8. Watch the chargers show Ext. control (with a managed battery), and check the total charge current stays within the limit at the dock, with shore power and solar both on.

From the command line, the main switches are D-Bus settings — /Settings/Services/Bol (DVCC, 0 off / 1 on) and /Settings/SystemSetup/MaxChargeCurrent (amps, −1 for no limit) in com.victronenergy.settings; the Venus OS command-line guide has the others. Switching DVCC off with Multis present prompts a VE.Bus reset in the menu, so use the menu for that.


The configurator's 35 ft sailboat: five Lithium NG 51.2 V batteries (25.6 kWh) with a Lynx Smart BMS NG 500 A, a MultiPlus-II 48/5000 on shore power, a SmartSolar 150/45 on 2 kWp of panels, and an Orion-Tr Smart 48/12-30 for the 12 V house supply.

PartUnder DVCC?How it's controlled
MultiPlus-II charger and inverteryesfollows the BMS's CVL, CCL and DCL
SmartSolar MPPTyesfollows the limits, first in line for charge current
Orion-Tr 48/12no — it's a load on the 48 V bankthe BMS's ATD contact, or its remote on/off
Motor controllerno — it's a loadthe BMS's ATD contact or contactor, or CAN to the controller
A SmartShunt on the 12 V house side—set as a DC system meter so DVCC adds that current to the charge limit

Because the Lynx Smart BMS NG forces DVCC on and SVS on, and STS off, most of the configuration is already done. The design work is in the right-hand column: making sure everything DVCC can't reach is switched by the BMS. The Lithium NG and Lynx Smart BMS NG guide covers that wiring, and the charger guide the sizing.


Mistakes to avoid

  • Enabling DVCC for a third-party battery that isn't listed as supported. Check its compatibility page first.
  • Ignoring Error #48. Update the device it names before relying on DVCC.
  • Expecting DVCC to control a Skylla-i, an unconnected alternator or the motor controller. Wire ATC and ATD, or use a supported regulator.
  • Setting charge voltages in VEConfigure or VictronConnect with a managed battery and expecting them to apply. The battery's CVL does.
  • Leaving Limit managed battery charge voltage on after commissioning.
  • Putting VE.Can and BMS-Can devices on one bus.
  • Adding a second Multi through an MK3-USB without checking whether it should follow the battery, and that several units together can't exceed its charge limit.

Sources

Checked on 15 November 2026:

  • Victron Energy — Ekrano GX, Cerbo GX, Nucleo GX manual: chapter 12, DVCC — Distributed Voltage and Current Control (features, requirements and firmware table, charge algorithm, several Multis, charge current limit and priorities, SVS, STS, SCS, controlling BMS, managed battery charge voltage, CAN-bus BMS behaviour, ESS); CAN-bus profiles and the VE.Can/BMS-Can rule; DC system shunts; Wakespeed WS500 and Arco Zeus integration; GX Error #48
  • Victron Energy — Battery compatibility: tested battery brands, third-party BMSes, warranty and support statements
  • Victron Energy on GitHub — gui-v2: DVCC settings paths and values
  • MG Energy Systems — Master LV installation guidance on the MG NMEA2000 protocol and controlling BMS, as summarised in our MG Energy Systems guide

We are not affiliated with Victron Energy.


Want exact numbers for your boat?

Use the configurator to generate a vendor-ready spec sheet.

Start the configurator
TPublished by TMHNovember 15, 2026
About & methodology