ElectricPropulsion.org
Repower calculator, guides & CAN tools

Signal K on a Cerbo GX: setup, NMEA 2000, Victron data and apps

Running Signal K server on a Cerbo GX: enabling it, securing it, the NMEA 2000 port mapping, how Victron data appears in Signal K, apps, reading data from code, backups and limits — from Victron's and Signal K's documentation.

TTMH9 min read11 sections
Charging
On this page
  1. Signal K, Node-RED, or neither?
  2. Step 1: install Venus OS Large and enable Signal K
  3. Step 2: open the admin page and secure it
  4. Step 3: connect NMEA 2000
  5. How Victron data appears in Signal K
  6. Apps
  7. Reading the data from your own code
  8. Storage, backups and recovery
  9. A checklist for a boat
  10. Sources
  11. Related reading

Signal K is an open data standard for boats, and Signal K server is the software that puts it to work: it collects data from NMEA 2000, NMEA 0183 and other sources, translates it into one consistent JSON format, and serves it to apps over a REST API and WebSockets. On a Cerbo GX running Venus OS Large, it runs on the Cerbo itself — so the batteries, chargers and solar the Cerbo already knows about sit alongside position, wind, depth and engine data from the NMEA 2000 network, in one place, for any app that speaks Signal K.

This guide covers enabling and securing it, connecting NMEA 2000, how Victron data appears, apps and code, and backups. It is based on Victron's Venus OS Large page, the Victron Venus plugin's documentation and source code, and the Signal K server documentation and specification, linked under Sources.

Before you start. Signal K is community software. Victron's page says plainly: "Do not contact normal Victron support for any help on SignalK" — help is on the Signal K Discord and GitHub. Victron also warns that Signal K and Node-RED are resource-intensive, and that an overloaded GX device will eventually reboot, interrupting battery monitoring and DVCC while it restarts. And Signal K isn't a display by itself: it is the data hub that apps and dashboards read from.


Signal K, Node-RED, or neither?

You wantUse
To see and control the Victron systemThe GX screen, Remote Console and VRM — nothing extra
To automate things: switch a relay, raise an alarmNode-RED
One data hub for navigation and electrical data, for chart and dashboard appsSignal K
Apps such as a browser chart plotter, anchor alarms or logging to a databaseSignal K plus the apps

Both come with Venus OS Large, and you can run both — on a faster Cerbo. The MK3 vs MK2 guide covers that headroom; Victron warns that running both on its slowest device "will very likely overload" it.


Step 1: install Venus OS Large and enable Signal K

  1. Settings → General → Firmware → Online updates: set Image type to Large, then check for updates and install.
  2. Set the access level to User & Installer (Settings → General → Access & Security); Victron requires it to switch Large features on.
  3. Settings → Integrations → Venus OS Large Features → Signal K: enable it.

From the command line, it's a D-Bus setting on the platform service — see the Venus OS command-line guide:

dbus -y com.victronenergy.platform /Services/SignalK/Enabled SetValue 1

Step 2: open the admin page and secure it

On the boat's network, open http://venus.local:3000, or the Cerbo's IP address on port 3000. Victron's documentation gives this as a plain HTTP address.

Create an admin user first. Victron's setup step is to go to Security → Users, create an admin user and protect it with a strong password. Until you do, anyone on the boat's WiFi can change the server's configuration. Signal K's own documentation adds that creating an admin account also enables the Restart button.

From anywhere, open the installation on the VRM Portal and use the Venus OS Large menu. Victron notes it can be slow, depending on the boat's connection. Don't forward port 3000 on the boat's router.


Step 3: connect NMEA 2000

Signal K reads NMEA 2000 straight from one of the Cerbo's CAN ports, and Victron has set it up for the recommended one already. The port has to stay on a 250 kbit/s "VE.Can & NMEA2000" profile (Settings → Connectivity → VE.Can port → CAN-bus profile).

DevicePort labelInterface in Signal KNotes
Cerbo GX MK2, Ekrano GXVE.Can 1vecan0isolated; enabled in Signal K by default; Victron's recommendation
Cerbo GX MK2, Ekrano GXVE.Can 2vecan1not isolated
Cerbo GX (original)VE.Cancan0enabled in Signal K by default
Cerbo GX (original)BMS-Cancan1can't be used for NMEA 2000 in Signal K

Victron's table predates the MK3. The MK3 has the same ports as the MK2, so check the interface names under Server → Connections in Signal K.

Wiring. Connect VE.Can 1 to the NMEA 2000 backbone with Victron's VE.Can to NMEA 2000 cable, and keep the backbone terminated at both ends — the NMEA 2000 wiring guide covers termination, power and the 48 V trap. If a managed battery uses BMS-Can at 500 kbit/s, it goes on the other port — VE.Can and BMS-Can must never share a bus. See Cerbo GX vs Cerbo GX MK2.

Watch for duplicates. If the Cerbo's NMEA2000-out is also on, the same battery and inverter data reaches Signal K twice: once from the Victron plugin, and once as NMEA 2000 messages from the Cerbo's virtual devices. Use Signal K's source priority settings to choose one, or turn NMEA2000-out off if nothing else on the network needs it. The Lithium NG PGN guide shows what the Cerbo sends.

NMEA 0183. Add a USB serial adapter as a connection under Server → Connections. Victron's warning: don't use the built-in serial ports /dev/ttyO0, /dev/ttyO2, /dev/ttyO4 or /dev/ttyO5 — they are the Cerbo's VE.Bus and VE.Direct ports — and once Signal K uses a USB serial port, Venus OS no longer does.


How Victron data appears in Signal K

The Victron Venus plugin (signalk-venus-plugin) is pre-installed and reads the Cerbo's own data over its internal D-Bus. Its settings are under Server → Plugin Config. It publishes Signal K paths like these, where <instance> is the device's instance number on the Cerbo:

Signal K pathFromUnit
electrical.batteries.<instance>.voltagebattery monitor or BMSV
electrical.batteries.<instance>.currentbattery monitor or BMSA
electrical.batteries.<instance>.capacity.stateOfChargebattery monitor or BMSratio, 0–1
electrical.batteries.<instance>.capacity.timeRemainingbattery monitor or BMSs
electrical.solar.<instance>.panelPowerMPPTW
electrical.solar.<instance>.yieldTodayMPPTJ (joules)
tanks.<fluid>.<instance>.currentLeveltank senderratio, 0–1

Signal K always uses SI units and ratios — the specification says the same key always has the same unit, so speed over ground is "always meters per second, never knots". That's why state of charge is 0.85, not 85 %, and temperatures are in kelvin. Apps convert for display.

It can write, too. The plugin accepts Signal K PUT requests for a handful of Victron settings — among them the inverter/charger mode, the AC input current limits and the GX relay's state. Treat that as you would any remote control of the boat's power system: keep the admin account locked down.


Apps

Signal K's Appstore (Appstore in the admin page) adds two kinds of software: plugins, which process data or connect protocols, and webapps, which are user interfaces in the browser. It needs the Cerbo to be online.

  • Freeboard-SK, a browser chart plotter, comes pre-installed with Venus OS Large, as does the Victron plugin.
  • The Appstore has dashboards, anchor alarms, data loggers and more, published by the Signal K community. Check each one's resource use before leaving it running on the Cerbo.

Pre-installed plugins are part of the read-only firmware image and can't be removed. Appstore → Installed → Update writes a newer version to the data partition, which Signal K then prefers; deleting that copy with the bin icon returns to the image's version.


Reading the data from your own code

Signal K's specification defines a REST API and a WebSocket stream on the server's port:

Address
Discoveryhttp://venus.local:3000/signalk
RESThttp://venus.local:3000/signalk/v1/api/
WebSocket streamws://venus.local:3000/signalk/v1/stream

Your own boat is vessels/self. Read the battery state over REST:

curl -s http://venus.local:3000/signalk/v1/api/vessels/self/electrical/batteries/

The stream sends deltas — only what changed — as JSON:

{
  "context": "vessels.urn:mrn:imo:mmsi:234567890",
  "updates": [
    {
      "source": { "label": "N2000-01", "type": "NMEA2000", "src": "017", "pgn": 127488 },
      "timestamp": "2010-01-07T07:18:44Z",
      "values": [{ "path": "propulsion.0.revolutions", "value": 16.341667 }]
    }
  ]
}

That example is from the Signal K specification: engine speed from NMEA 2000 PGN 127488, in revolutions per second. With security enabled, clients have to authenticate or be granted access before they can read or write; Signal K server's security documentation covers how.

If you'd rather read Victron values without Signal K, the Cerbo's own Modbus TCP and MQTT interfaces do that directly — see the Lynx Smart BMS guide.


Storage, backups and recovery

Where it lives. Configuration, installed plugins and plugin data are in /data/conf/signalk; logs are in /data/log/signalk-server. Both survive firmware updates.

USB-stick tools from Victron. Put the file on a USB stick and reboot the Cerbo:

FileDoes
venus-data-00-backup-data-partition.tgzcopies all of /data to the stick — a full backup, Signal K included
venus-data-20-signalk-reset.tgzdeletes everything in /data/conf/signalk/
venus-data-30-signalk-delete-data-logs.tgzdeletes only Signal K's log files

Full data partition. Below 5% free space the Cerbo raises warning #46, and Signal K may refuse to start. Keep only most recent data log files under Server → Settings is on by default; leave it on, and use the log-delete stick if space runs out.

Updates. Signal K server is updated with Venus OS releases. Victron describes a manual update over SSH, but marks it unsupported: it changes the read-only system partition, which the next firmware update overwrites.


A checklist for a boat

  • An admin user with a strong password, created the first time you open the page.
  • NMEA 2000 on VE.Can 1 at 250 kbit/s; any BMS-Can battery on the other port.
  • One source for each value: Signal K's source priorities, or NMEA2000-out off.
  • Remote access through VRM, not a forwarded port.
  • A full /data backup before firmware updates, with the backup stick.
  • An eye on CPU, memory and free space after adding apps — and Signal K or Node-RED, not both, on a Cerbo that struggles.

Sources

Checked on 15 November 2026:

  • Victron Energy — Venus OS Large: Signal K and Node-RED: installation and access level, admin address, creating the admin user, VE.Can port and interface table, CAN profile, NMEA 0183 serial ports, pre-installed plugins and updates, file locations, USB backup and reset files, warning #46, manual update, VRM access, resource and support statements
  • Signal K — signalk-venus-plugin README and source (src/mappings.ts, src/venusToDeltas.ts): connection over D-Bus, Signal K path mapping, units and the settings that accept PUT requests
  • Signal K — signalk-server README: what the server does, NMEA 2000 via canboatjs, the Appstore, admin account, support on Cerbo GX
  • Signal K — Specification 1.7.0: REST API and discovery endpoints, and the data model (SI units, delta format example)
  • Victron Energy on GitHub — gui-v2: Venus OS Large Features menu and the platform-service setting
  • Victron Energy — Ekrano GX, Cerbo GX, Nucleo GX manual: VE.Can and BMS-Can on separate buses

We are not affiliated with Victron Energy or the Signal K project.


Want exact numbers for your boat?

Use the configurator to generate a vendor-ready spec sheet.

Start the configurator
TPublished by TMHNovember 15, 2026
About & methodology