CAN frame decoder
Paste an identifier and the data bytes to see every field by name, with units: 639 NMEA 2000 PGNs, J1939 engine data and DM1 fault codes, and CANopen network management, heartbeat, SDO and emergency messages. Add your own DBC file to decode any message it defines.
29-bit ID 0x09F21401
How it works
NMEA 2000 layouts come from canboat, the open-source PGN database that Signal K server's NMEA 2000 input (canboatjs) is built on. Values are little endian; the top of a field's range means “not available” and the value below it “error”. SI units (rad, K, m/s, Pa, C) are shown with a friendlier conversion next to them.
Victron and MG Energy Systems also send proprietary register messages — Victron VREGs and MG MGREGs on PGN 61184 — for values with no standard PGN. The decoder names the registers from the makers' own documents (state of charge, cell min/max, BMS state, charge limits, device state and more). Where canboat marks a PGN's layout as unverified, the decoder says so; for the new Electric Energy Storage PGNs it uses the layout MG Energy Systems publishes instead.
Messages longer than 8 bytes travel as fast-packet frames. Paste the reassembled payload here, or the raw frames into the log analyzer, which puts them back together.
J1939: SAE's parameter database isn't public, so only engine parameters published in manufacturer manuals are decoded — engine speed and torque, load, coolant temperature, oil pressure, battery voltage, fuel level, engine hours — plus DM1 lamps and fault codes (SPN, FMI, occurrence count).
CANopen: NMT commands, heartbeat states, expedited SDO reads and writes with abort codes, and emergency messages with the error register. PDO contents depend on each device's mapping, so they're shown raw — decode them with the signal calculator, or with a DBC file that describes the mapping.
DBC files: add a .dbc file and any frame it defines is decoded with its signal names, scaling, units and value tables, ahead of the built-in decoders. Pick a message from the file to fill in its identifier. A 29-bit message the DBC defines for one source address also matches the same PGN from other addresses. The same DBC support is in the log analyzer, for whole logs.
Other CAN tools
Everything is decoded in your browser — logs and frames are never uploaded. Message layouts come from these documents; where a source doesn't define something, the tools show the raw bytes rather than guess.
- canboat — NMEA 2000 PGN database v9.0.0 (Apache License 2.0) — NMEA 2000 PGN layouts, lookups and fast-packet / ISO transport framing
- DynaGen (Cattron) TOUGH Series J1939 Reference Manual 9M02-9252-A201 — J1939 engine PGNs/SPNs, DTC layout
- Mecc Alte MxK CAN-Bus Technical Guide — J1939 DM1 lamp bits and values
- Schneider Electric Machine Expert — IoDrvJ1939 FMI (ENUM) — J1939 FMI names
- Faulhaber Communications Manual 7000.05050 (CANopen protocol description) — CANopen COB-IDs, NMT, heartbeat, SDO, abort codes, EMCY
- Victron — VE.Can registers (public) — Victron VREG register messages (PGN 61184)
- MG Energy Systems — Master LV Communication Guide v1.42.0.0 — MG MGREG registers, and the Electric Energy Storage PGN layouts (128003, 127491, 127495)
The NMEA 2000 definitions are derived from canboat, © 2009–2026 Kees Verruijt, under the Apache License 2.0. NMEA 2000® is a registered trademark of the National Marine Electronics Association; canboat's definitions are reverse-engineered, not the official NMEA database. Check critical values against your equipment's documentation.