How an electric boat's CANopen motor controller is organised and read: the object dictionary, SDO reads, PDO mapping and transmission types, NMT states and heartbeat, emergency messages, and what EDS and DCF files are — with Sevcon Gen4 and Curtis examples.

TTMH12 min read12 sections
Motors & drives
On this page
  1. The object dictionary: everything has an address
  2. COB-IDs: who sends what
  3. SDO: read or write one entry
  4. PDO: live data without overhead
  5. NMT: the network states
  6. EMCY: the device tells you something went wrong
  7. EDS: the device's data sheet, in a file
  8. DCF: one configured device
  9. Two real controllers
  10. Reading your own controller
  11. Sources
  12. Related reading

Many electric boat motor controllers — including the ones Victron's GX devices support: Sevcon Gen4, the Curtis 123x E/SE and F series, and DMC — talk CANopen, not NMEA 2000. CANopen is a higher-layer protocol from the CAN in Automation group (CiA) that runs on an ordinary CAN bus with 11-bit identifiers. Once you understand four ideas — the object dictionary, SDO, PDO and the EDS/DCF files that describe a device — a controller stops being a black box: you can read its battery current and motor speed, see why it faulted, and configure what it sends.

This guide explains each of them from Faulhaber's CANopen communications manual, CiA's description of the CiA 306 file formats, a real EDS from the open-source CANopenNode stack, and the objects Victron's open-source driver reads from Sevcon and Curtis controllers. The sources are listed at the end.


The object dictionary: everything has an address

Every CANopen device keeps all its parameters, setpoints and measured values in an object dictionary (OD). Each entry has a 16-bit index and an 8-bit subindex, so "battery voltage" is not a message but an address such as 0x5100, subindex 1. The communication services described below are just ways of reading and writing those addresses.

The index ranges are fixed by CiA 301:

IndexWhat lives there
0x1000–0x1FFFCommunication objects: device identity, PDO settings, heartbeat, error register
0x2000–0x5FFFManufacturer-specific objects — each maker's own parameters and measurements
0x6000–0x6FFFStandardised device-profile objects; for drives, the CiA 402 profile

A few objects you'll meet on every device:

  • 0x1001 — error register, a bit field summarising the current fault classes.
  • 0x1008 — device name, a text string (longer than 4 bytes, so it needs a segmented SDO read).
  • 0x1018 — identity: subindex 1 is the vendor ID, subindex 2 the product code.
  • 0x6040 / 0x6041 — the CiA 402 controlword and statusword, which drive a servo's state machine.
  • 0x606C — the CiA 402 velocity actual value.

How much of the profile range a controller uses varies. The two controllers below show both extremes.


COB-IDs: who sends what

A CANopen identifier (the COB-ID) is 11 bits: a 4-bit function code and a 7-bit node ID (1–127). The predefined connection set gives every node a fixed set of identifiers derived from its node ID:

ObjectCOB-ID
NMT command0x000
SYNC0x080
Emergency (EMCY)0x080 + node ID
TxPDO 1 / 2 / 3 / 4 (sent by the device)0x180 / 0x280 / 0x380 / 0x480 + node ID
RxPDO 1 / 2 / 3 / 4 (received by the device)0x200 / 0x300 / 0x400 / 0x500 + node ID
SDO reply from the device0x580 + node ID
SDO request to the device0x600 + node ID
NMT error control (boot-up, heartbeat)0x700 + node ID

So a controller at node 1 replies to SDOs on 0x581, sends its heartbeat on 0x701 and its first TxPDO on 0x181. The PDO, SYNC and EMCY identifiers can be changed in the object dictionary; the SDO identifiers can't. "Tx" and "Rx" are always seen from the device: a TxPDO is something the controller sends.


SDO: read or write one entry

A Service Data Object transfer reads (uploads) or writes (downloads) exactly one OD entry, addressed by index and subindex. A client — a laptop tool, a PLC, a Victron GX — sends a request and the device answers. Every SDO frame is 8 bytes:

Byte 0Bytes 1–2Byte 3Bytes 4–7
Command specifierIndex (little endian)SubindexData (up to 4 bytes)

Values of up to 4 bytes travel in one exchange (expedited transfer). Longer values, like the device name in 0x1008, need a segmented transfer over several frames.

Example: read a Sevcon Gen4's battery voltage. Victron's driver reads it from 0x5100 subindex 1 and scales it by 0.0625 V. For a controller at node 1:

Request  0x601   40 00 51 01 00 00 00 00   upload 0x5100 sub 1
Reply    0x581   4B 00 51 01 20 03 00 00   2 bytes of data: 0x0320

0x0320 = 800, and 800 × 0.0625 = 50.0 V. Decode the reply in the frame decoder. If the object doesn't exist, the device answers with an abort instead, carrying a 32-bit abort code — 0x06020000 means "object does not exist in the object dictionary".

SDOs are simple and always available, but every value costs two frames and a round trip. That's fine for configuration and slow monitoring; it's why live data normally goes in PDOs.


PDO: live data without overhead

A Process Data Object is a plain CAN frame of up to 8 bytes whose bytes are OD values — no index, no command byte, just data. A controller can send motor speed, current and temperature in one PDO many times a second.

  • TxPDOs are sent by the device, typically with measured values.
  • RxPDOs are received by the device, typically with commands and setpoints.
  • PDOs flow only when the device is in the NMT Operational state (see below).

Each PDO is described by two OD records:

Communication parametersMapping parameters
RxPDO 1–40x1400–0x14030x1600–0x1603
TxPDO 1–40x1800–0x18030x1A00–0x1A03

PDO mapping: which values go where

The mapping record lists, in order, the OD entries packed into the PDO. Subindex 0 is the number of mapped entries; each following subindex is a 32-bit mapping entry:

0x607A0020
  607A  = index
    00  = subindex
    20  = length in bits (0x20 = 32)

So 0x1A00 sub 0 = 2, sub 1 = 0x606C0020, sub 2 = 0x51000110 would make TxPDO 1 carry the 32-bit velocity actual value followed by the 16-bit 0x5100 subindex 1 — six bytes in all. An entry can only be mapped if the device allows it: the EDS marks each object with PDOMapping=1 or 0. Changing a mapping has to follow the sequence CiA 301 lays down, which configuration tools handle; get it wrong and the device answers with an SDO abort such as 0x06090030 (value range) or 0x06020000. A mapping with zero entries switches the PDO off.

For an RxPDO shared by several devices, a node can skip bytes meant for others with a dummy mapping to a data-type index (0x0005 for an 8-bit unsigned, 0x0006 for 16-bit, 0x0007 for 32-bit…).

Many drives come with the CiA 402 "PDO set for servo drives" as their default — for example RxPDO 1 carrying the controlword (0x6040) and TxPDO 1 the statusword (0x6041) — which you can then change (dynamic mapping).

Transmission type: when a PDO is sent

The communication record's transmission type sets the trigger:

Transmission typeBehaviour
0Synchronous, acyclic: sent (or acted on) after a SYNC message, only when the content changed
1–240Synchronous, cyclic: sent after every nth SYNC message
252TxPDO only: data captured at SYNC, sent when requested by a remote frame
253TxPDO only: sent when requested by a remote frame
255Asynchronous: sent on an event defined by the device or profile

SYNC is a message with no data on COB-ID 0x080. It lets one master make every node sample or act at the same instant — useful when several controllers must change torque together.


NMT: the network states

Every CANopen device runs the same small state machine, driven by NMT commands from the master on COB-ID 0x000:

StateWhat works
InitialisationEntered at power-on; the device then sends a boot-up message and moves on by itself
Pre-operationalSDO and NMT only — this is where you configure it
OperationalEverything, including PDOs
StoppedNMT only

An NMT command is two bytes, a command specifier and the target node ID (0 = all nodes):

CommandByte 0
Start (→ Operational)0x01
Stop0x02
Enter pre-operational0x80
Reset node0x81
Reset communication0x82

A device that never sends PDOs is often just sitting in Pre-operational, waiting for a Start it never got.

To show it's alive, a device sends a heartbeat on 0x700 + node ID at a configurable interval, with one byte giving its state. Older systems used node guarding, where the master polls instead. The boot-up message uses the same identifier.


EMCY: the device tells you something went wrong

When a fault occurs, the device sends an emergency message on 0x080 + node ID, without being asked. It is 8 bytes: a 16-bit error code, the error register (0x1001), and up to five manufacturer-specific bytes. Codes come in families — in Faulhaber's list, for example, 0x3210 overvoltage, 0x3220 undervoltage and 0x4310 temperature error — and a code of 0x0000 says the fault has cleared. Manufacturers add their own: Victron's Sevcon driver carries a table of Sevcon codes such as 0x45C3 Low battery cutout.


EDS: the device's data sheet, in a file

An Electronic Data Sheet describes a CANopen device as delivered. CiA defines the format in CiA 306-1: a text file with the extension .eds, describing "functions and properties of any not configured CANopen device". It lists every object in the object dictionary — its name, data type, read/write access, default value and whether it can be mapped into a PDO — plus device-level facts such as the supported bit rates and the number of PDOs. The device vendor normally provides it.

Tools use the EDS to show the object dictionary by name instead of raw indices, to build PDO mappings, and to decode traffic. The format is ASCII text in bracketed sections with key=value lines. Here is an excerpt from the EDS that ships with the open-source CANopenNode stack:

[DeviceInfo]
ProductName=New Product
BaudRate_250=1
BaudRate_500=1
NrOfRXPDO=4
NrOfTXPDO=4
LSS_Supported=1

[1800]
ParameterName=TPDO communication parameter
ObjectType=0x9
SubNumber=0x6

[1800sub1]
ParameterName=COB-ID used by TPDO
ObjectType=0x7
DataType=0x0007
AccessType=rw
DefaultValue=$NODEID+0xC0000180
PDOMapping=0

Each object gets a section named after its index ([1800]), and each subindex its own ([1800sub1]). DataType=0x0007 is an unsigned 32-bit value, AccessType=rw means read/write, and $NODEID+… means the default depends on the node ID — the EDS can't know it, because it describes the device type, not a device in your boat.

DCF: one configured device

That's what the Device Configuration File is for. A DCF is generated from the EDS and is also a text file, with the extension .dcf; it adds the configuration the EDS lacks — "used bit rate, node-ID and parameter value", in CiA's words. In practice it gains a [DeviceCommissioning] section with the node ID and bit rate, and ParameterValue entries on objects whose values differ from the defaults.

Think of the EDS as the controller's catalogue page and the DCF as the record of your controller: node 3, 250 kbit/s, with this PDO mapping and these limits. Configuration tools can write a DCF back to a replacement unit, and it documents the installation. CiA also publishes an XML schema for device descriptions (CiA 311), alongside the EDS/DCF text formats.


Two real controllers

Victron's open-source GX driver reads these values, and the difference shows how far "CANopen" can vary between makers:

ValueSevcon Gen4Curtis 123x E/SE
Battery voltage0x5100 sub 1, × 0.0625 V0x324C, × 0.015625 V
Battery current0x5100 sub 2, signed, × 0.0625 A0x359E, × 0.1 A
Motor speed0x606C (CiA 402), rpm0x3207, rpm
Motor temperature0x4600 sub 30x320B, × 0.1 °C
Controller temperature0x5100 sub 40x322A, × 0.1 °C

The Sevcon mixes the standard CiA 402 profile (motor speed in 0x606C) with its own manufacturer range; the Curtis keeps everything in manufacturer-specific objects. Neither is wrong — but it means an EDS, or the maker's manual, is essential: the profile alone won't tell you where the battery current is. A third maker, emDrive, lists CANopen with the DS402 drive profile (CiA 402) in its L30 controller's datasheet.

Identification varies too. The driver first reads the device name from 0x1008; its comments note that Curtis 123x SE/E controllers don't implement 0x1008 at all, and that one DMC firmware aborts it with 0x06020000, so it falls back to the vendor ID in 0x1018. The Cerbo GX motor-drive guide covers the GX side.


Reading your own controller

  1. Get the EDS from the controller maker — it's the map of everything below.
  2. Match the bit rate. The EDS lists what the device supports; Victron's GX, for example, reads these controllers at 250 or 500 kbit/s.
  3. Find the node ID: power the controller up while logging and look for its boot-up and heartbeat on 0x700 + node ID.
  4. Identify it: read 0x1018 sub 1 and 2 by SDO.
  5. Read values by SDO from the addresses in the EDS, scaled as the maker documents.
  6. Watch its PDOs for live data once it's Operational — the mapping objects (0x1A00…) tell you what each byte is.

The site's CAN log analyzer sorts CANopen traffic by function code and decodes NMT, SYNC, heartbeat, SDO and EMCY frames; the frame decoder does the same for single frames. A PDO's bytes depend on that device's mapping, so the tools identify PDOs but can't name their contents — load a DBC describing them, or read the mapping objects.


Sources

Checked on 23 November 2026:

  • Faulhaber — Communications Manual 7000.05050, 7th edition (CANopen protocol description to CiA 301): object dictionary ranges, communication services, predefined connection set and COB-IDs, PDO communication and mapping objects, mapping entries and dummy mappings, transmission types, the CiA 402 default PDO set, SDO frame layout and abort codes, EMCY layout and codes, SYNC, NMT state machine and commands, boot-up, heartbeat and node guarding
  • CAN in Automation — CiA 306: Electronic Device Description: EDS and DCF definitions, file extensions, what the DCF adds, the parts of CiA 306
  • CSS Electronics (Martin Falch) — CANopen EDS file explained: EDS normally provided by the device vendor; section and key=value format; the DCF's DeviceCommissioning section and ParameterValue entries
  • CANopenNode on GitHub — example DS301_profile.eds (Apache License 2.0): the EDS excerpt
  • Emsiso — emDrive L30 datasheet V2.5: CANopen with the DS402 profile
  • Victron Energy on GitHub — dbus-canopen-motordrive: Sevcon Gen4 and Curtis E/SE objects and scaling, device identification through 0x1008 and 0x1018, the Sevcon error table